Accurate hematoma volume estimation in chronic subdural hematoma (cSDH) is crucial for clinical decision-making. The commonly used 1/2ABC formula, originally developed for small, regular hematomas, may be inaccurate for cSDH due to its irregular morphology. A rapid, reliable, and practical method for bedside assessment is needed. This post hoc analysis of a multicenter, real-world study compared seven simplified computed tomography-based formulas with volumetric measurements obtained using three-dimensional (3D) Slicer in a derivation cohort of 129 patients with cSDH. We further evaluated the newly proposed 3.5/6SH formula in an independent validation cohort of 60 additional patients. Accuracy, agreement, and efficiency were evaluated using estimation error, percentage deviation, intraclass correlation coefficients (ICCs), and Bland–Altman (BA) analysis. In the derivation cohort, the 3.5/6SH formula yielded the lowest median volume deviation (−0.82 mL, interquartile range IQR 13.12 mL), the smallest percentage deviation (−1.00%, IQR 17.08%), and the highest ICC (0.973), indicating high accuracy and close agreement with the 3D Slicer reference standard. In contrast, the widely used 1/2ABC formula exhibited a larger negative percentage deviation (−4.64%) and a lower ICC (0.910). BA analysis further confirmed that 3.5/6SH had the narrowest limits of agreement and a clinically acceptable maximum absolute percentage deviation (29.33%), whereas the maximum deviation for 1/2ABC (65.04%) exceeded the clinical acceptability threshold (33%). In an independent validation cohort of 60 patients, 3.5/6SH maintained a small bias (median deviation −1.29 mL; percentage deviation −1.27%) and excellent agreement with 3D Slicer (ICC = 0.979). Inter- and intrarater ICCs for 3.5/6SH measurements in the validation cohort were 0.994 and 0.998, respectively, supporting excellent reproducibility. The average calculation time was 77.95 sec for 3.5/6SH—longer than for 1/2ABC (35.95 sec), but substantially shorter than for 3D Slicer (19.04 min). The 3.5/6SH formula showed high accuracy and agreement with 3D Slicer across all metrics and offers a reliable, simplified method for bedside cSDH volume estimation that may facilitate more consistent volume assessment in multicenter research and clinical practice, particularly for more sensitive monitoring of hematoma changes in resource-limited environments.
Building similarity graph...
Analyzing shared references across papers
Loading...
T. C. Liu
Biao Zhao
Yang Liu
Journal of Neurotrauma
UNSW Sydney
Capital Medical University
The George Institute for Global Health
Building similarity graph...
Analyzing shared references across papers
Loading...
Liu et al. (Mon,) studied this question.
www.synapsesocial.com/papers/69706c87b6488063ad5c1957 — DOI: https://doi.org/10.1177/08977151251414140
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: