Overall mortality in patients aged ≥90 years who underwent pacemaker implantation was 30.9%, primarily linked to high Clinical Frailty Scale scores and comorbidities.
110 consecutive patients aged ≥90 years who underwent permanent pacemaker (PM) implantation between January 1, 2020, and November 30, 2024
Permanent pacemaker implantation
Overall mortality and one-year mortalityhard clinical
In patients aged ≥90 years undergoing pacemaker implantation, mortality is primarily driven by baseline frailty and comorbidities rather than the procedure itself.
Abstract Permanent pacemaker (PM) implantation is the treatment of choice for various bradyarrhythmias and is increasingly common in nonagenarian and centenarian patients due to rising life expectancy. This study aimed to assess mortality and prognostic factors in this patient population. This observational, retrospective study included consecutive patients aged ≥90 years who underwent PM implantation between January 1, 2020, and November 30, 2024. Mortality rates were evaluated, and variables associated with higher mortality were investigated. Clinical and demographic data were retrieved from electronic medical records. A total of 110 patients were included, 76 alive and 34 deceased. Mean age was similar between groups (92.5 years vs. 92.9 years, p 0.537). Overall mortality was 30.9%, with a mean follow-up of 433 days. The Clinical Frailty Scale (CFS) was more frequently ≥6 in deceased patients (79.4% vs. 52.6%, p 0.008). Deceased patients also showed a higher prevalence of dementia (29.4% vs. 10.8%, p 0.016), cerebrovascular disease (29.4% vs. 11%, p 0.018), and severe left ventricular dysfunction (SLVD) (2.1% vs. 0%, p 0.03). No significant differences were observed in clinical presentation or electrocardiographic findings. Single-chamber PMs were more common in the deceased group (82.4% vs. 53.9%, p 0.004). Deceased patients also had a higher mean number of emergency department visits per patient, both for all causes (4.44 vs. 1.28, p 0.004) and cardiovascular causes (0.76 vs. 0.24, p 0.004). To calculate one-year mortality while accounting for potential follow-up losses or data import misses, we compared patients who died within 365 days of the procedure with those who attended at least one follow-up visit beyond this period. We identified 75 patients fitting these criteria, 61 were alive and 14 deceased within the first year, resulting in a one-year mortality rate of 18.7%. Deceased patients more frequently had a CFS score ≥6 (92.9% vs. 57.4%, p 0.013) and dementia (35.7% vs. 11.7%, p 0.028). Complication rates were similar between groups (0% vs. 3.4%, p 0.492), and no significant differences were identified in other analyzed variables. In our study, overall mortality was 30.9% with an average follow-up of 433 days, primarily associated with elevated CFS scores, dementia, cerebrovascular disease, and SLVD. One-year mortality was 18.7%, predominantly linked to overall patient frailty. The indication for PM implantation did not influence outcomes and was not associated with significant complications.
Building similarity graph...
Analyzing shared references across papers
Loading...
E Oliveira
J Goncalves
Gonçalo Pestana
European Heart Journal
Hospital de São João
Building similarity graph...
Analyzing shared references across papers
Loading...
Oliveira et al. (Sat,) reported a other. Overall mortality in patients aged ≥90 years who underwent pacemaker implantation was 30.9%, primarily linked to high Clinical Frailty Scale scores and comorbidities.
www.synapsesocial.com/papers/698586238f7c464f2300a160 — DOI: https://doi.org/10.1093/eurheartj/ehaf784.577