Accurate and real-time polyp segmentation is essential for early colorectal cancer detection, yet remains challenging due to small, low-contrast lesions and the computational demands of many deep learning models. We propose LGPS, a Lightweight GAN-based Polyp Segmentation framework that achieves high segmentation accuracy with minimal computational overhead. LGPS integrates a MobileNetV2-based generator enhanced with Residual Squeeze-and-Excitation (ReSE) blocks and a discriminator equipped with Convolutional Conditional Random Fields (ConvCRF) to refine spatial coherence and boundary precision. A hybrid loss function — combining Binary Cross-Entropy, Weighted IoU, and Dice Loss — improves class imbalance handling and sensitivity to small or blurry polyps. LGPS is an extremely compact model, requiring only 1.07 million parameters — over 17 × smaller than many recent transformer- and CNN-based SOTA architectures — while preserving high segmentation accuracy. In quantitative evaluation, LGPS achieves a Dice score of 0.7299 and an IoU of 0.7867 on the multi-center PolypGen dataset, the most challenging benchmark in polyp segmentation. On the widely used CVC-ClinicDB dataset, LGPS attains the highest IoU (0.9238) among lightweight and transformer-based approaches. The model also runs at 100.08 FPS on 256 × 256 inputs, demonstrating true real-time capability. Stratified evaluation and qualitative results further confirm its robustness on small and low-contrast lesions. These results highlight LGPS as a computationally efficient yet high-performing framework suitable for real-time clinical deployment. The code is available at https://github.com/Falmi/LGPS/ . • Introduces LGPS, a lightweight GAN-based model for real-time polyp segmentation. • Integrates MobileNetV2 with ReSE blocks and a ConvCRF discriminator for refined predictions. • Proposes a novel hybrid loss (BCE + WIoU + Dice) to enhance generalization to small or low-contrast polyps. • Achieves 0.7299 Dice on PolypGen and 0.9238 IoU on CVC-ClinicDB with only 1.07M parameters. • Delivers real-time performance at over 100 FPS, making it suitable for deployment in clinical endoscopy systems.
Building similarity graph...
Analyzing shared references across papers
Loading...
Fiseha Berhanu Tesema
Alejandro Guerra-Manzanares
Tianxiang Cui
Biomedical Signal Processing and Control
Ningbo University
University of Nottingham Ningbo China
Building similarity graph...
Analyzing shared references across papers
Loading...
Tesema et al. (Tue,) studied this question.
www.synapsesocial.com/papers/69a7603fc6e9836116a2ccc6 — DOI: https://doi.org/10.1016/j.bspc.2026.109777