This paper proposes a digital potentiometer-based adaptive gas sensor interface for stable detection without signal saturation under extreme environmental fluctuations. Conventional fixed-gain circuits often suffer from limited dynamic range, leading to data loss when severe baseline drifts exceed ADC input limits. To address this, we developed a real-time control algorithm that actively adjusts attenuator and amplifier gains, maintaining the ADC input voltage (VADC) near the common-mode voltage (VCM). Experimental results demonstrate that the interface remains stable even when the buffer voltage reaches 2.75 V, significantly surpassing the 1.2 V ADC limit. Sensor resistance data, reconstructed by inversely calculating updated circuit parameters, achieved high accuracy with a Mean Absolute Percentage Error (MAPE) of 1.628% and a maximum relative error under 4.8%. Consequently, this study proves that logically extending the physically limited ADC dynamic range enables high-precision gas sensing in diverse environments without requiring high-performance computing devices. This approach provides a cost-effective and robust solution for compact IoT-based gas monitoring systems.
Building similarity graph...
Analyzing shared references across papers
Loading...
Soon-Kyu Kwon
Hyeon‐June Kim
Sensors
Seoul National University of Science and Technology
Building similarity graph...
Analyzing shared references across papers
Loading...
Kwon et al. (Tue,) studied this question.
www.synapsesocial.com/papers/69fc2c4b8b49bacb8b347da5 — DOI: https://doi.org/10.3390/s26092887