In previously reported experimental studies on T-head square-neck one-sided bolted (TSOB) beam-to-square hollow section (SHS) column joints, bolt pull-out failure caused by the bulge deformation of the column wall has been identified as a typical failure mode. To prevent SHS wall deformation under the bending moment at the beam ends and to improve the deformation capacity of the joint, this paper proposes assembled H-steel strengthening measures for beam-column joints. Monotonic static load tests were conducted on four joints with H-steel components to explore the influence of the length and plate thickness of the strengthening components on the structural response of the joints. The test results showed that the H-steel components prevented bolt pull-out failure and increased the yield and peak bending moments of the joints by 69.3%-72.6% and 22.5%-39.4%, respectively. It is recommended that TSOB beam-to-SHS column joints use extended H-steel components, the cross-section of which should be designed according to the internal force of the joint.
Building similarity graph...
Analyzing shared references across papers
Loading...
Xingang XU
Lele SUN
Guanghui NIU
Industrial Construction
Building similarity graph...
Analyzing shared references across papers
Loading...
XU et al. (Wed,) studied this question.
www.synapsesocial.com/papers/69fd7ec6bfa21ec5bbf070ec — DOI: https://doi.org/10.3724/j.gyjzg23111205